Rotor, bucket, tube rack, table for the model 2420
Catalogue DownloadPDF logo

Rotor Name Nominal Capacity Tube Size (mm)
diam. x length
Maximum Speed
(rpm)
Maximum RCF
(xg)(*1)
Bucket Code No. Tube Rack Adaptor Code No.
Swinging Bucket Rotor
RS-240
(*2)
48 x 1.5/2mL(*3) 9.5-11 x 36-60 4,000 1,950 053-5040 -
40 x 6mL RIA tube(*3) 12.5-13.3 x 36-80 4,000 1,970 053-5030 -
24 x 5-7mL narrow blood collecting tube /10mL(*4,5) 12.5-13.3 x 46-105 4,000 2,430 053-5850 -
4 x 7-10mL blood collecting tube/15mL(*6) 15-17.2 x 86-110 4,000 2,540 053-4910 -
4 x 15mL Conical (TC) 17 x 121 4,000 2,580 053-4910 -
8 x 7-10mL blood collecting tube/15mL(*6) 15-17.2 x 86-110 4,000 2,520 053-4900 -
8 x 15mL Conical (TC) 17 x 121 4,000 2,580 053-4900 -
16 x 7-10mL blood collecting tube/15mL(*6) 15-17.2 x 86-110 4,000 2,500 053-4980 -
24 x 7-10mL blood collecting tube/15mL(*6) 15-17.2 x 89-105 4,000(*7) 2,490 053-7340 -
4 x 7-10mL blood collecting tube/15mL(*6) 15-17.8 x 87-110 4,000 2,500 053-4990 055-7400(*8)
4 x 50mL 27-37 x 95-110 4,000 2,540 053-4990 -
4 x 50mL Conical (TC) 30 x 117 4,000 2,560 053-5010 -
4 x 15mL/50mL Conical (TC) 17 x 121/30 x 117 4,000 2,610/2,500
053-5010 055-6010(*9)
TOPTOP
Microplate Rotor
RMP-23 6 x Microplate 86(W) x 128(D) x 52(H) 4,000 1,790 Equipped with rotor -
2 x Deep-well Plate
(*1) To show the RCF exactly, input the rotation radius. At the factory, the rotation radius is pre-set at 14.6cm.
The above Maximum RCF is the calculated value at the maximum speed at each rotation radius.
(*2) Buckets and adaptors are optional.
(*3) Tube support can be produced for special tube sizes. Contact our distributor.
(*4) Blood collecting tubes made by SEKISUI (Insepack II), Termo (Venoject II), Nipro (Neotube) or Beckton Dickinson (Vacutainer) can be used.
(*5) Upto 16tubes of 5/7mL Termo (Venoject II) tubes can be used.
(*6) Blood collecting tubes made by SEKISUI (Insepack II), Termo (Venoject II), Nipro (Neotube) or Beckton Dickinson (Vacutainer) can be used.
(*7) In the case of 15mL taper tubes, please operate at 3,000rpm or less. Bucket 053-7340 is exclusively used with 2420.
(*8) In case of using glass tube, rubber cushion 024-1400 is necessary.
(*9) This adaptor is used commonly for both 15mL and 50mL conical tubes.