KUBOTAimage
Home
Product
+2810
  + Specification
  + Rotor List
  + Rotor, Bucket,
     Tube Rack,
     Adaptor Table

  + More information
Company Overview
G-force Calculation
Contact Distributor
Contact Us
Site Map
ISO logo
KUBOTA's plant in Fujioka has become ISO9001 certified since 1996.
More information on the 2810 model
Catalogue DownloadPDF logo

Pre-cooling
Some samples are easily deactivated at normal temperature. In such cases, pre-cooling enables the samples to reach a low temperature before the experiment, thus avoiding deactivation of valuable samples.


Memory flashing function (Patent pending)
The memory flashing function makes the spin-down easy and simple by storing previous spinning time automatically, then recalling repeatedly. Pressing the flashing key, same operation whose spinning time is from 1 second to 90 seconds can be repeated.


Three channel memory settings
The memory setting function makes routine work easy and simple, storing centrifugal speed, RCF and time. It is possible to save, recall and operate the centrifugal condition just by pushing the program switches.


Tachometer-port
The 2810 has a tachometer-port on its lid to check the actual speed. The validation of the speed sensor by measuring the actual speed is highly needed for stringent GMP requirements.


Five types of notification sounds
The notification sound can be selected from one buzzer and 4 melodies. This will be useful to identify each unit when several units are used in the same room.
And also, mute setting is available.


Acceleration/Deceleration (Two-level switching)
The 2810 model provides two-level switching for both acceleration and deceleration, corresponding to application requirements. For example, in those cases where one must avoid whirring up the samples, a slow deceleration can be programmed so as to achieve the desired conditions and most accurate results.


Digital display and control knob
The control knob and digital display provide users with an easy-to-operate interface. The control knob is much easier to set than up-down-keys, and the degital display clearly indicates each parametier.


Indication of the correct RCF value
Actual rotation radius can be set and indication of correct RCF is realized.


Balancing of the sample
The 2810 model enables one to reduce the experiment time, allowing centrifugal separation to be carried out with eye measured sample balancing. With its tolerable inbalance sensor, it is not necessary to balance the sample with remarkable accuracy. In addition, the operation is smooth and it maintains a quiet environment.
TOPTOP