| Rotor, bucket, tube rack, table for the
5930 model |
  |
| Rotor
Name |
Nominal
Capacity |
Tube
Size (mm)
diam. x length |
Maximum
Speed
(rpm) |
Maximum
RCF
(xg) |
Bucket
Code No. |
Tube
Rack Adaptor Code No. |
| Swinging
Bucket Rotor |
| RS-3012M |
140
x 6mL/RIA tube |
10-12
x 65-100(95)(*4) |
3,300 |
2,150(*1) |
053-5310 |
055-5830 |
| 80
x 5/7mL narrow blood collecting tube(*2) |
12-13.3
x 63-110 |
3,300 |
2,280 |
053-5310 |
055-5000 |
| 100
x 10mL |
12-14.5
x 75-110(105)(*4) |
3,300 |
2,280 |
053-5310 |
055-5840 |
| 80
x 5-10mL narrow or thick blood collecting tube/15mL
(*2) |
12-17.2
x 72-110 |
3,300 |
2,280 |
053-5310 |
055-0900 |
| 80
x 15mL(64) |
14.5-17.2
x 75-110(105)(*4) |
3,300 |
2,280 |
053-5310 |
055-5850 |
| 16
x 15/50mL |
15mL
14.5-17.2 x 75-135(125)(*4) |
3,300 |
2,280 |
053-5310 |
055-5860 |
| 50mL
27-36 x 75-115(110)(*4) |
| 48
x 15mL Conical (TC) |
17
x 121(121)(*4) |
3,300 |
2,280 |
053-5310 |
055-4660 |
| 24
x 50mL Conical (TC) |
30
x 117(117)(*4) |
3,300 |
2,280 |
053-5310 |
055-4610 |
| 8
x 100mL |
38-46.5
x 75-120(116)(*4) |
3,300 |
2,280 |
053-5310 |
055-5870 |
| 4
x 175mL
Conical(*4) |
61
x 118 |
3,300 |
2,280 |
053-5310 |
055-6880 |
| 4
x 200mL
Conical(*4) |
61
x 130 |
3,300 |
2,280 |
053-5310 |
055-6880 |
| 4
x 225mL
Conical(*4) |
61
x 137 |
3,300 |
2,280 |
053-5310 |
055-6880 |
| 4
x 250mL
(*4) |
60-61.8
x 100-141(136)(*4) |
3,300 |
2,280 |
053-5310 |
055-6880 |
| 4
x 350mL |
65-71
x 100-130(122)(*4) |
3,300 |
2,280 |
053-5310 |
055-6890 |
sputum
tube
(self-standing type)(*5) |
- |
- |
- |
- |
- |
| 96
x 10mL |
12-14
x 75-110 |
3,300 |
2,240(*1) |
053-5180 |
055-0200 |
| 72
x 15mL |
14.5-17.2
x 75-110 |
3,300 |
2,280 |
053-5180 |
055-0210 |
| 16
x 50mL |
27-36
x 75-114 |
3,300 |
2,280 |
053-5180 |
055-0240 |
| 48
x 15mL Conical (TC) |
17
x 121 |
3,300 |
2,280 |
053-5180 |
055-0220 |
| 16
x 50mL Conical (TC) |
30
x 117 |
3,300 |
2,280 |
053-5180 |
055-0230 |
| 4
x 175mL
Conical(*4) |
61
x 118 |
3,300 |
2,280 |
053-5180 |
055-4490 |
| 4
x 200mL
Conical(*4) |
61
x 130 |
3,300 |
2,280 |
053-5180 |
055-4490 |
| 4
x 225mL
Conical(*4) |
61
x 137 |
3,300 |
2,280 |
053-5180 |
055-4490 |
| 4
x 250mL(*4) |
60-61.8
x 100-141 |
3,300 |
2,280 |
053-5180 |
055-4490 |
| 4
x 350mL |
65-71
x 100-130 |
3,300 |
2,280 |
053-5180 |
055-5880 |
| 4
x 500mL
Conical (*6) |
96
x 147 |
3,300 |
2,280 |
053-5180 |
431124
(*6) |
| 4
x 650mL |
84-86
x 100-125 |
3,300 |
2,280 |
053-5180 |
055-5890 |
| 4
x 750mL |
95-97.5
x 100-135 |
3,300 |
2,280 |
053-5180 |
- |
| 8
x Microtiter Plate(*2) |
88(W)
x 134(D) x 50(H) |
3,300 |
2,020(*1) |
053-5220 |
- |
| 4
x Deep-well Plate(*2) |
| 8
x Microtiter Plate(*2) |
92(W)
x 133(D) x 36(H) |
2,000 |
770(*1) |
053-5170 |
055-5900 |
| 8
x Tissue-culture Plate(*2) |
2,000 |
770(*1) |
053-5170 |
- |
RS-3020M
(*5) |
76 x 15mL |
12-17.2 x 72-116 |
4,000 |
3,200(*1) |
Bucket
included |
055-1380 |
| 48
x 15mL Conical (TC) |
17
x 121 |
4,000 |
3,400(*1) |
Bucket
included |
055-0300 |
| 16
x 50mL |
27-36
x 100-117 |
4,000 |
3,310(*1) |
Bucket
included |
055-0330 |
| 20
x 50mL Conical (TC) |
30
x 117 |
4,000 |
3,420 |
Bucket
included |
055-0310 |
| 4
x 500mL Conical (TC) |
96
x 147 |
4,000 |
3,430 |
Bucket
included |
431124
(*7) |
TOP |
| Microtiter
Plate Rotor |
| PT-89M |
8
x Microtiter Plate(*7) |
86(W)
x 130(D) x 89(H) |
2,400 |
1,080 |
Bucket
included |
055-6370
(*9) |
| 4
x Deep-well Plate(*7) |
| PT-745M |
12
x Microtiter Plate(*7) |
86(W)
x 128(D) x 90(H) |
4,200 |
3,100 |
Bucket
included |
055-6380
(*9) |
| 4
x Deep-well Plate(*7) |
| Fixed
Angle Rotor |
| RA-410M3 |
8
x 12mL
Plastic tube (*10) |
15.9-16.5
x 97-120 |
8,500 |
9,370 |
- |
055-1120 |
| 8
x 14mL
(*11) |
17
x 100 |
8,500 |
9,130 |
- |
055-0550 |
| 8
x 15mL Conical tube |
17
x 121 |
8,500 |
9,530 |
- |
055-1280 |
| 8
x 50mL
Plastic tube(*12) |
26.4-29.2
x 98-115 |
8,500 |
9,290 |
- |
055-1110 |
| 8
x 50mL Conical tube |
30
x 117 |
8,500 |
9,690 |
- |
- |
| Sartorius |
Vivaspin
2 |
16.7
x 129 |
8,500 |
9,530 |
- |
055-1280 |
| Vivaspin
6 |
16.7
x 129 |
8,500 |
9,530 |
- |
055-1280 |
| Vivaspin
20 |
30
x 117 |
8,500 |
9,690 |
- |
- |
| Millipore |
Amicon
Ultra-4 |
17
x 129 |
8,500 |
9,530 |
- |
055-1280 |
| Amicon
Ultra-15 |
30
x 121 |
8,500 |
9,690 |
- |
- |
TOP |
|
|
| (*1) |
More information for
the display of centrifugal force and the detection of
over speed, please refer the Instruction Manual. |
| (*2) |
5/7mL
narrow tube made by Sekisui (Insepack II), Termo (Venoject
II) Nipro (Neotube) and Becton Dickinson (Vacutenar) can
be used. Tube for flow cytometry can be used. |
| (*3) |
The length inside ()
includes the length of shield cover (code no. 027-9210). |
| (*3) |
When shield covers are
used, tubes cannot be inserted in the tube holes at the
four corners of the bucket. Accordingly, the number of
tubes for each bucket is reduced by four tubes. (Example:
When 15mL glass tubes are used in bucket S13215, up to
32 tubes can be used). |
| (*4) |
175 mL Falcon conical
tube (code no. 352076)
needs a cushion (code no. 352090).
200 mL Nalge Nunc conical tube (code no. 376813)
needs a cushion adapter (code no. 377585).
225 mL Falcon conical tube (code. no. 352075)
needs a cushion (code no. 352090). |
| (*5) |
Several types of sputum
tube will be acceptable with RS-3012 and 053-5310 bucket.
For more information, please contact your local dealer. |
| (*6) |
A bottle made by Corning
must be used (Code No. 431123).
And also cushion adapter made by Corning is required (Code
No. 431124). |
| (*7) |
If microtiter plates
are used, it is possible to stack them in double or more
on each bucket. However, be sure to test the strength
of those plates prior to centrifugation. The microtiter
plate at the bottom may be crushed. |
| (*9) |
The adapters 055-6370
is available (Option). This adapter makes it convenient
to handle a micro titer plate , especially some microtiter
plates are stacked. |
| (*10) |
The NALGENE Round-Bottom
Centrifuge Tubes (Cat. No. 3110-0120
and 3117-0120
can be used. |
| (*11) |
The BD FalconTM
Round Bottom Test Tubes (Cat. No.352006,
352018
and 352059)
can be used. |
| (*12) |
The NALGENE Round-Bottom
Centrifuge Tubes (Cat. No. 3110-0120
and 3117-0120
can be used. |
TOP |
|
|