| More information on the 6200 model |
  |
Memory flashing (Patent pending) |
| The memory flashing function
makes the spin-down easy and simple by storing previous
spinning time automatically then recalling repeatedly.
Pressing the flashing key, same operation whose spinning
time is from 1 second to 90 seconds can be repeated. |
|
Five channel memory settings |
| The memory setting function
makes routine work easy and simple, storing centrifugal
speed, RCF and time. It is possible to save, recall and
operate the centrifugal condition just by pushing the
program switches. |
|
Rotor compatibility with micro centrifuge |
| The 6200 has a rotor
compatible with other micro refrigerated centrifuges (3700
series) and 3400. Thus, those who posses a 3700 series
or 3400 can enjoy sharing rotor with 6200. |
|
Automatic rotor identification (Patent pending)
and one-touch rotor function |
| The automatic rotor identification
and one-touch rotor functions, developed using KUBOTA's
advanced technologies, facilitate easy interchange of
rotors. These functions enable changing rotors, corresponding
to applications’ requirements, without setting the
rotor IDs or fastening rotors. |
|
Biohazard-proof
Rotor |
Certified biohazard-proof
rotors to ensure all aerosols and liquid from samples
remain between the rotor and its lid (CAMR test certified).
 |
|
Multi rotor for micro tubes, MF-2236 |
| The MF-2236, a multi
rotor for micro tubes, provides a reasonable solution
to apply various types and sizes of tubes simply by changing
buckets. For example, the MF-2236 accepts 8 PCR-strips,
and 0.4, 0.5 and 2mL tubes. |
|
TOP |
g.sec integrator function |
| The g.sec integrator
function optimizes the protocols in those cases where
customers need to achieve exactly the same centrifugal
effect. One can obtain the same effect just by setting
the g.sec value in the 6200 model. The g.sec integrator
function enables one to control centrifuge spins with
the same centrifugal effect and to calculate g.sec value. |
|
Acceleration/Deceleration (Three-level switching) |
| The 6200 model provides
Three-level switching for both acceleration and deceleration,
corresponding to application requirements. For example,
in those cases where one must avoid whirring up the samples,
a slow deceleration can be programmed so as to achieve
the desired conditions and most accurate results. |
|
Tachometer-port |
| The 6200 has a tachometer-port
on its lid to check the actual speed. The validation of
the speed sensor by measuring the actual speed is highly
needed for stringent GMP requirements. |
|
Alarm indicator and automatic stop
functions |
| Various alarm indicators
and automatic stop functions improve safety further and
stop the operation immediately after activation in the
case of an emergency. The 6200 model is equipped with
an alarm indication function including imbalance detection,
abnormally high temperature detection, speed sensor and
temperature sensor fault detection. The rotor sensor detects
whether the rotor is set correctly to the drive shaft
(patent pending). In addition, the unit is fitted with
a circuit breaker. |
|
Foot pedal
(Option) |
| An optional foot pedal
(option) allows hands-free lid opening, enabling the interlock
mechanism to be released by a foot pedal. |
|
TOP |