| Rotor, bucket, tube rack, table for the
8920 model |
  |
| Rotor
Name |
Maximum Capacity |
Tube Sizes (mm)
diam. x length |
Maximum Speed
(rpm) |
Maximum RCF
(xg) |
Bucket
Code No. |
Tube
Rack
Adaptor Code No. |
| Swinging
Bucket Rotor |
RS-730
(*1) |
80
x RIA tube |
12
x 75-110 |
4,200 |
3,590 |
S13215 |
S18005 |
| 48
x 7mL blood collecting tube |
12.5-13
x 75-106 |
4,200 |
3,590 |
S13215 |
S18012 |
| 48
x 15mL(*3) |
15.5-17
x 96-115 |
4,200 |
3,590 |
S13215 |
S18015 |
| 16
x 15mL Conical (TC) |
16.5
x 120.6 |
4,200 |
3,590 |
S13215 |
S18016 |
| 8
x 50mL Conical (TC)(*2) |
29.5
x 117 |
4,200 |
3,590 |
S13215 |
S18052 |
| 160
x RIA tube(*4) |
12
x 75-110 |
4,000 |
3,450 |
S13420 |
S18005 |
| 96
x 7mL blood collecting tube(*4) |
12.5-13
x 75-106 |
4,000 |
3,450 |
S13420 |
S18012 |
| 96
x 15mL(*3,4) |
15.5-17
x 96-115 |
4,000 |
3,450 |
S13420 |
S18015 |
| 40
x 15mL Conical (TC) |
16.5
x 120.6 |
4,000 |
3,450 |
S13420 |
S18615 |
| 32
x 15mL Conical (TC)(*4) |
16.5
x 120.6 |
4,000 |
3,450 |
S13420 |
S18016 |
| 24
x 50mL Conical (TC) |
29.5
x 117 |
4,000 |
3,450 |
S13420 |
S18650 |
| 16
x 50mL Conical (TC)(*4) |
29.5
x 117 |
4,000 |
3,450 |
S13420 |
S18052 |
| 28
x 50mL Conical (TC) |
29.5
x 117 |
4,200 |
3,750 |
S13235 |
- |
| 4
x 500mL(*6) |
69
x 159 |
4,000 |
3,720 |
S13520 |
- |
| 64
x RIA·7mL blood collecting tube |
12-16
x 60-85 |
4,000 |
3,830 |
S13550 |
S17356 |
| 40
x 15mL attached caps |
17-19.4
x 107 |
4,000 |
3,830 |
S13550 |
S17357 |
| 48
x 15mL |
15.5-17
x 96-115 |
4,000 |
3,830 |
S13550 |
S17358 |
| 36
x 15mL Conical (TC) |
16.5
x 120.6 |
4,000 |
3,830 |
S13550 |
S17359 |
| 12
x 50mL |
34
x 100 |
4,000 |
3,830 |
S13550 |
S17375 |
| 16
x 50mL Conical (TC) |
29.5
x 117 |
4,000 |
3,830 |
S13550 |
S17377 |
| 16
x 50mL Conical (TC) |
Self-Standing
29.5 x 117 |
4,000 |
3,830 |
S13550 |
S17378 |
| 4
x 250mL Bottle/230mL Glass tube(*7) |
61.5
x 125/57 x 135 |
4,000 |
3,830 |
S13550 |
S17405/S17401 |
| 4
x 500mL |
69
x 159 |
4,000 |
3,830 |
S13550 |
S13555 |
| 4
x 750mL |
85
x 170 |
4,000 |
3,830 |
S13550 |
- |
| 12
x Micro plate(*5) |
86(W)
x 130(D) x 49(H) |
4,200 |
3,180 |
S13220 |
- |
| 4
x Deep-well Plate(*6) |
4,200 |
3,180 |
S13220 |
- |
TOP |
| Microtiter
Plate Rotor |
| PT-20 |
6
x Micro plate(*5) |
85(W)
x 128(D) x 52(H) |
4,000 |
1,790 |
Bucket
included |
- |
| 2
x Deep-well Plate(*5) |
| PT-21 |
6
x Micro plate(*5) |
86(W)
x 130(D) x 62(H) |
5,000 |
3,100 |
Bucket
included |
- |
| 2
x Deep-well Plate(*5) |
| PT-89 |
8
x Micro plate(*5) |
86(W)
x 130(D) x 89(H) |
2,400 |
1,080 |
Bucket
included |
055-6370
(*8) |
| 4
x Deep-well Plate(*5) |
| PT-745 |
12
x Micro plate(*5) |
86(W)
x 128(D) x 90(H) |
4,200 |
3,100 |
Bucket
included |
055-6380
(*9) |
| 4
x Deep-well Plate(*5) |
| Fixed
Angle Rotor |
| RA-288M3 |
24
x 12mL |
15.9-16.5
x 97-120 |
8,500 |
9,690 |
- |
- |
| RA-410M3 |
8
x 15mL Conical (TC) |
17
x 121 |
8,500 |
9,530 |
- |
055-1280 |
| 8
x 50mL Conical (TC) |
30
x 117 |
8,500 |
9,690 |
- |
- |
| RA-500M2 |
10
x 50mL |
26.4-29.2
x 98-121 |
8,500 |
9,690 |
- |
- |
|
|
| (*1) |
Shielded covers are sold
separately. The packet S13215 shield cover is divided
into code No. S17112 (made of PC) and S17113 (made of
PP). The packet S13420 shield cover is divided into code
No. S17114 (made PC) and S17115 (made of PP). The packet
S13550 sealing cap is code No. S17135 (made of PC). |
| (*2) |
FALCON®, SARSTEDT®,
Lab-Tek®, GREINER (White), and IWAKI 50 mL conical
tube can use shield covers. |
| (*3) |
When shielded covers
are used, tubes cannot be inserted in the tube holes at
the four corners of the bucket. Accordingly, the number
of tubes for each bucket is reduced by four tubes. (Example:
When 15 mL glass tubes are used in bucket S13420, up to
80 tubes can be used.) |
| (*4) |
The code No. S13420 bucket
uses two tube racks each (a total of eight) in one bucket.
Do not use this bucket when a different type of a tube
rack is contained in this bucket to prevent a danger. |
| (*5) |
When micro plates are
used, the plates exceeding two stages can be piled up
in each bucket. However, use the plates after testing
their strength before centrifugation. The micro plate
at the lower stage may be crushed. |
| (*6) |
This bucket is divided
into adapters (S13174 and S13175 combined jointly) for
NALGEN® 175 mL type bottom bottle (3143-0175). Contact
us. |
| (*7) |
250 mL bottle adapter
(S17405) and 230 mL glass tube adapter (S17401) |
| (*8) |
The adapters 055-6370
is available (Option). This adapter makes it convenient
to handle a micro titer plate , especially some microtiter
plates are stacked. |
| (*9) |
The adapters 055-6380
is requiered (Option). |
TOP |
|
|